ATM offers a series of High-Power precision attenuators covering the waveguide sizes WR28 through WR430 and attenuation values of 10dB, 20dB, 30dB, 40dB and 50dB.   The assembly construction includes a precision element for optimum electrical performance, but note that Attenuation vs. Frequency can vary greatly depending on the attenuation at a given frequency.  For more information feel free to call us and discuss your needs with one of our design engineers.


GENERAL SPECIFICATIONS ( All Options )

Electrical

Std. Attenuation values: 10, 20, 30, 40, 50dB

Nominal Attenuation accuracy: +/- 0.50dB

(+/- 0.75dB for WR42, WR34, WR28)

Freq. Sensitivity: +/- 0.60 dB

(+/- 0.75dB for WR42, WR34, WR28)

Applicable Mil-Specs

General:

Product Specific:

Mechanical

Size: See Tables

Body: Aluminum

Finish: Hi-Temp Black

 


Waveguide Fixed High Power Precision Attenuators

WG Size Freq. (GHz) VSWR Power
Watt
Standard
Model No.*
Dimensions Outline
Length (L)
Inches
Offset (O)
Inches
WR430 1.70 - 2.60 1.15 1200 430-630HPA-dB-2-2 54.0 2.230  
WR340 2.20 - 3.30 1.15 1200 340-630HPA-dB-2-2 42.0 1.780  
WR284 2.60 - 3.95 1.15 1200 284-630HPA-dB-6-6 33.0 1.420  
WR229 3.30 - 4.90 1.15 1000 229-630HPA-dB-2-2 27.0 1.209 Dwg
WR187 3.95 - 5.85 1.15 750 187-630HPA-dB-6-6 24.0 0.936  
WR159 4.9 - 7.05 1.15 625 159-630HPA-dB-2-2 24.0 0.859  
WR137 5.95 - 8.20 1.15 500 137-630HPA-dB-2-2 22.5 0.686  
WR112 7.05 - 10.0 1.15 425 112-630HPA-dB-6-6 16.0 0.561  
WR90 8.20 - 12.4 1.15 225 90-630HPA-dB-6-6 14.5 0.450  
WR75 10.0 - 15.0 1.15 200 75-630HPA-dB-6-6 13.5 0.425  
WR62 12.4 - 18.0 1.15 100 62-630HPA-dB-6-6 11.5 0.351  
WR51 15.0 - 22.0 1.15 100 51-630HPA-dB-6-6 11.5 0.295  
WR42 18.0 - 26.5 1.15 100 42-630HPA-dB-6-6 9.5 0.210 Dwg
WR34 22.0 - 33.0 1.15 75 34-630HPA-dB-6-6 9.5 0.210 Dwg
WR28 26.5 - 40.0 1.15 75 28-630HPA-dB-6-6 9.0 0.180 Dwg
*Insert desired attenuation value (10, 20, 30, 40, or  50dB) in the model number where dB is listed
See ATM Flange page for more information on flanges.
The Model numbers listed above are the most common model numbers for size, material, flanges, and calibration, however, these models can easily be altered to accommodate customer needs by following the Model # code system below.

In addition the customer must choose the attenuation value appropriate for application (10dB, 20dB, 30dB, 40dB, or 50dB) and insert it in the model number where dB is listed.

Ordering Information

                     Typical Part #:         WGSize- 630HP Material- dB value-  Flange1- Flange2
              

Example: P/N: 284-630HPA-20-6-6  is:
WR284 high power fixed attenuator - Alum. Material - 20dB Attenuator - Cover Flg.- Cover Flg.

 

 


Home | Coaxial Components | Waveguide Components | Catalog | Ordering Info | Sales RepresentativesContact Us | Request a Quote

Advanced Technical Materials Inc
49 Rider Avenue
Patchogue, NY 11772

 

Voice: (631) 289-0363
Fax: (631) 289-0358
Email: atm@atmmicrowave.com
URL:
http://www.atmmicrowave.com


©2001-2007 Advanced Technical Materials, Inc. All Rights Reserved.